TOP > Category > Coaxial > ARR Series
Outline
ARR series protects the device from the surge voltage, utilizing the gas discharge tube.
It prevent the surge voltage from circuits of the base station.
Features
・The gas discharge tube is installed.
・Due to wide frequency band, it can be applied to many applications.
・The terminal lug is available for grounding.
・N, TNC and SMA interface are available. Regarding other interface, please contact our sales.
Specifications
Characteristic Impedance 50Ω
Dielectric Withstanding Voltage 100V AC(rms)/1minute
Insulation Resistance 100MΩ min. at 100V DC
Contact Resistance 6mΩ max.
V.S.W.R N type 1.2max. at DC to 6GHz
TNC type 1.25max. at DC to 6GHz
SMA(DM) type 1.2max. at DC to 3GHz
Insulation Loss 0.3dB max. at DC to 6GHz
DC Breakdown Voltage 150V min.at 100V/sec.
Inpact Breakdown Voltage 700V min. at 1000V/μ sec.
Max. Inpactdischarge Current 10KA max. (8/20micro sec.)
Operating Temperature -55~+85℃